Thermocouples
RTDs
Strain Gages
Dynamic
Voltage & Current
Frequency
Temperature&Humidity

Signal Conditioning
Sensor
Software
Data Acquisition

ULT20 Built-in IC Piezoelectric Accelerometers
ULT20 built-in IC piezoelectric accelerometers combine electronic amplifiers to the general piezoelectric accelerometers and provide direct connection to readout devices. The measurement process becomes simpler and accuracy is improved. It is sensor driven by a 4mA(2-10mA) constant current provided by the signal conditioner. The ULT20 built-in IC piezoelectric accelerometer is the most popularly used in today's testing. Their specifications are featured below: Low-impedance voltage output signal results in reduced electrical noise.Excellent signal-to-noise, convenience mounting.Stability, and excellent protection against the influx of moisture, oils, or other potential contaminants.
 Model  Description
 ULT2001  100mV/g Sensitivity,50g Amplitude range,30kHz Resonant  frequency,0.5-8000Hz(10%) Frequency range...more
 ULT2002V  5mV/g Sensitivity,500g Amplitude range,50kHz Resonant  frequency,0.5-12000Hz(10%) Frequency range...more
 ULT2003V  50mV/g Sensitivity,100g Amplitude range,32kHz Resonant  frequency,0.35-10000Hz(10%) Frequency range...more
 ULT2004  100mV/gSensitivity,50g Amplitude range,27kHz Resonant  frequency,0.5-8000Hz(10%) Frequency range...more
 ULT2005  250mV/g Sensitivity,20g Amplitude range,23kHz Resonant  frequency,0.35-5000Hz(10%) Frequency range...more
 ULT2006  1000mV/g Sensitivity,5g Amplitude range,6kHz Resonant  frequency,0.05-1500Hz(10%) Frequency range...more
 ULT2007  100mV/gSensitivity,50g Amplitude range,22kHz Resonant  frequency,0.5-5000Hz(10%) Frequency range...more
 ULT2008  500mV/gSensitivity,10g Amplitude range,15kHz Resonant  frequency,0.35-4000Hz(10%) Frequency range...more
 ULT0109  100mV/g Sensitivity,50g Amplitude range,22kHz Resonant  frequency,0.5-5000Hz(10%) Frequency range...more
 ULT2010  100mV/g Sensitivity,50g Amplitude range,25kHz Resonant  frequency,0.5-5000Hz(10%) Frequency range...more
 ULT2011  500mV/gSensitivity,10g Amplitude range,10kHz Resonant  frequency,0.5-2000Hz(10%) Frequency range...more
 ULT2012  100mV/gSensitivity,50g Amplitude range,23kHz Resonant  frequency,0.2-7000Hz(10%) Frequency range...more
 ULT2015  5000mV/g Sensitivity,1g Amplitude range,7kHz Resonant  frequency,0.1-1500Hz(10%) Frequency range
 ULT2016  10000mV/g Sensitivity,0.5g Amplitude range,1.2kHz Resonant  frequency,0.05-300Hz(10%) Frequency range
 ULT2019  500mV/g Sensitivity,10g Amplitude range,29kHz Resonant  frequency,0.7-8000Hz(10%) Frequency range
 ULT2020  1000mV/g Sensitivity,5g Amplitude range,18kHz Resonant  frequency,0.35-6000Hz(10%) Frequency range
 ULT2021  10000mV/g Sensitivity,0.5g Amplitude range,2kHz Resonant  frequency,0.1-150Hz(10%) Frequency range
 ULT2023  25mV/g Sensitivity,200g Amplitude range,33kHz Resonant  frequency,0.7-11000Hz(10%) Frequency range
 ULT2030  28000mV/g Sensitivity,0.18g Amplitude range,3kHz Resonant  frequency,0.35-1000Hz(10%) Frequency range
 ULT2031  1000mV/g Sensitivity,5g Amplitude range,5kHz Resonant  frequency,0.1-1000Hz(10%) Frequency range
 ULT2051  150mV/g Sensitivity,33g Amplitude range,30kHz Resonant  frequency,1-10000Hz(10%) Frequency range...more
 ULT2052  150mV/gSensitivity,50g Amplitude range,30kHz Resonant  frequency,0.5-10000Hz(10%) Frequency range...more
 ULT2053  150mV/g Sensitivity,33g Amplitude range, 27kHz Resonant  frequency,0.7-9000Hz(10%) Frequency range...more
 ULT2054  250mV/g Sensitivity,20g Amplitude range,23kHz Resonant  frequency,0.2-7000Hz(10%) Frequency range...more
 ULT2055  700mV/g Sensitivity,7g Amplitude range,12kHz Resonant  frequency,0.5-4000Hz(10%) Frequency range...more
 ULT2056  1500mV/gSensitivity,3g Amplitude range,7.5kHz Resonant  frequency,0.1-2000Hz(10%) Frequency range...more
 ULT2057  1mV/g Sensitivity,5000g Amplitude range,46kHz Resonant  frequency,1-20000Hz(10%) Frequency range
 ULT2058  30mV/g Sensitivity,166g Amplitude range,46kHz Resonant  frequency,1-18000Hz(10%) Frequency range
 ULT2059  10mV/g Sensitivity,500g Amplitude range,40kHz Resonant  frequency,1-12000Hz(10%) Frequency range...more
 ULT2060  200mV/g Sensitivity,25g Amplitude range,20kHz Resonant  frequency,1-4000Hz(10%) Frequency range...more
 ULT2061  1000mV/g Sensitivity,5g Amplitude range,5kHz Resonant  frequency,0.1-1000Hz(10%) Frequency range...more
 ULT2062  250mV/g Sensitivity,20g Amplitude range,21kHz Resonant  frequency,0.5-8000Hz(10%) Frequency range...more
 ULT2063  200mV/g Sensitivity,25g Amplitude range,15kHz Resonant  frequency,0.5-5000Hz(10%) Frequency range
 Comment:
1. The model with ¡°T¡± is top connector, without ¡°T¡± is side connector.
2. ULT20 Built-in IC Piezoelectric Accelerometers have the same specifications:
Linearity: ¡Ü1% ,Transverse sensitivity: ¡Ü5%, Typical: ¡Ü3%
Output bias voltage: 8-12VDC, Constant current excitation: 2-20mA, Typical: 4mA
Output impedance: <1500 ¦¸, Excitation voltage: 18-30VDC Typical: 24VDC
Temperature range: -40- +120¡æ, Discharge time constant: ¡Ý0.2second
Insulated impedance: >108 ¦¸, Mounting torque: 20-30kgf.cm (M5 screw thread)
 
 

Home | Products | Applications | Support | Contact