Thermocouples
RTDs
Strain Gages
Dynamic
Voltage & Current
Frequency
Temperature&Humidity

Signal Conditioning
Sensor
Software
Data Acquisition

ULT02 Signal Conditioners
ULT02 signal conditioners not only supply ULT01 built-in IC piezoelectric accelerometers excitation power, but can also make the output bias voltage go to zero. They provide gain,high-pass filter, low-pass filter and double integral etc. They also provide strong anti-jamming,low noise, and high accuracy at a low price.
 Model  Description
ULT0201
Measure mode: Acceleration, 8 Channels,0.01Hz Lower frequency,30kHz Upper frequency,4¦ÌV Noise,110Vac PowerSupplies,0.5 % Precision, Gain 1 to 100 .
ULT0202
 
Measure mode: Acceleration,1 Channels,0.1Hz Lower frequency,30kHz Upper frequency,3¦ÌV Noise,110Vac PowerSupplies,0.5 % Precision, Gain 0.1 to 100.
ULT0203
 
Measure mode: Acceleration, 6 Channels,0.1Hz Lower frequency, 30kHz Upper frequency,4¦ÌV Noise,110Vac PowerSupplies,0.5 % Precision, Gain 0.1 to 100 .
ULT0204
 
Measure mode: Acceleration,1 Channels,0.1Hz Lower frequency,30kHz Upper frequency,3¦ÌV Noise,110Vac PowerSupplies,0.5 % Precision, Gain 1 to 100 .
 
Measure mode: Velocity,1 Channels,1Hz Lower frequency,10kHz Upper frequency,2¦ÌV Noise,110Vac PowerSupplies,2 % Precision, Gain 1 to 100 .
 
Measure mode: Displacement,1 Channels,1Hz Lower frequency,1kHz Upper frequency,1¦ÌV Noise,110Vac PowerSupplies,3 % Precision, Gain 1 to 100 .
ULT0205
 
Measure mode: Acceleration,8 Channels,0.1Hz Lower frequency,30kHz Upper frequency,4¦ÌV Noise,110Vac PowerSupplies,0.5 % Precision, Gain 0.1 to 100 .
 
Measure mode: Velocity,8 Channels,1Hz Lower frequency,10kHz Upper frequency,3¦ÌV Noise,110Vac PowerSupplies,2 % Precision, Gain 0.1 to 100 .
 
Measure mode: Displacement,8 Channels,1Hz Lower frequency,1kHz Upper frequency,2¦ÌV Noise,110Vac PowerSupplies,3 % Precision, Gain 0.1 to 100 .
ULT0206
 
Measure mode: Acceleration,2 Channels,0.16Hz Lower frequency, 30kHz Upper frequency, 110Vac PowerSupplies, Gain 0.1 to 100
ULT0207
 
Measure mode: Constant Current supply,1 Channels Gain 1 18-30VDC PowerSupplies.
ULT0208
 
Measure mode: Acceleration,1 Channels, 0.1Hz Lower frequency, 30kHz Upper frequency,2¦ÌV Noise,18-30VDC PowerSupplies, Gain 1 to 100 .
ULT0209
 
Measure mode: Velocity,1 Channels, 1Hz Lower frequency,10kHz Upper frequency, ¡À15Vac PowerSupplies, Gain 1 to 100 .
 
Measure mode: Displacement,1 Channels, 1Hz Lower frequency,1kHz Upper frequency, ¡À15Vac PowerSupplies, Gain 1 to 100 .
 Comment:
1.The power of ULT0208 is DC18-30V or DC¡À5-18V, of ULT0209 is DC¡À15V and DC+24V.
2.We offer ULT0209 not only civil, but also industrial.
3.Channels of ULT0201 or ULT0205 can be changed per customer request.
 
 

Home | Products | Applications | Support | Contact